![]() ![]() I’ve written a few articles and guides related to PuTTY that might be of interest. It’s that simple! While You’re Still Here. reg file to import it into your registry. Make sure that PuTTY is closed before importing registry keys. Importing PuTTY Settings and Sessions to Another PC (Note that SSH keys are not stored in the registry so you will have to copy these manually if you have any). If you only want to export PuTTY sessions, run: regedit /e "%USERPROFILE%\Desktop\putty-sessions.reg" HKEY_CURRENT_USER\Software\SimonTatham\PuTTY\SessionsĪ file putty-sessions.reg should now be on your Desktop. If you want to export all PuTTY settings including sessions, run: regedit /e "%USERPROFILE%\Desktop\putty.reg" HKEY_CURRENT_USER\Software\SimonTathamĪ file putty.reg should now be on your Desktop. ![]() In Windows 10, open the Start Menu and type cmd, then right-click on the Command Prompt icon and click Run as Administrator. We can use Windows Command Prompt in administrative mode to easily export keys from the Windows Registry. After the sequence has executed, or you want to terminate the connection, use the appropriate steps from the "Close" folder in the "Session Management" folder to terminate the connection or any open connections.Firstly, make sure that all PuTTY windows are closed.DataRcv: variable to store the data received from the client after the command is sent.TimeCapture: The time, in seconds, to wait for receiving data back after the command is sent.Command: The command you want to execute on the device.ConnectionId: The ID you gave the connection in Initialize Connection step.After the connection has been established, a Send-Received Data step in the "Session Management" folder is used to retrieve information from the DUT.All other values can be left as default and changed if necessary.PortNumber: The port number to connect on.Protocol: The Internet protocol to use for the connection.ShowPuTTY: Enter either True or False to show the Putty terminal window on this machine.Login: The username for the remote device.ConnectionId : Unsigned long - it must be an integer greater than 0.TargetName: The IP address or domain name of the device to connect to.Here you can edit the connection settings as follows: In the Module tab in the Step Settings window. Navigate to the "Session Configuration" folder and insert the Initialize Connection step. To communicate with the device, you will need to initialize the connection.In the Insertion Palette, the folder, "ExtraPuTTY." should be added at the top.It is recommended that you select the Use Currently Loaded Type. When the Sequence Editor launches, you may see a Type Conflicts dialogue.Run the Sequence Editor with administrator privileges to mitigate this error. ![]() If you do not run with administrator privileges, you will get an error that states that the Sequence Editor "Could not copy ' \Components\TypePalettes\Install_ExtraPuTTY.ini' to '\Components\TypePalettes\ExtraPuTTY.ini'. Launch TestStand with administrator privileges.For example, if you are using TestStand 2016, change 3.0.0.0 and 3.3 to 16.0. Note: This requires administrator privileges. In a text editor, modify each mention of the 3.0.0.0 or 3.3 version of TestStand to the TestStand version you are using.Go to \Components\TypePalettes and open Install_ExtraPuTTY.ini. Once the installation is completed, navigate to the TestStand directory which you chose as the installation folder.Navigate to the TestStand directory, for example - C:\Program Files (x86)\National Instruments\TestStand 2016 After choosing the installation directory for ExtraPuTTY, you will see a prompt to choose the TestStand Install folder.In the "Choose Components" page, check the option for TestStand steps.The latest version is compiled with putty 0.67. Download and run the latest installer. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |